Noyes OFL 250 -50 Single-Mode Handheld OTDR
Price: $3,275.00
This item is in stock
|
OFL250-50... Noyes Handheld OTDR... Model Number... Description... OFL250-50U-ENG... 1550 nm, single-mode OTDR... ***IN STOCK - DELIVERED TO YOUR SITE WITHIN 72 HOURS ****... OFL250-50 Handheld, Fault-Locating OTDRThe Noyes OFL250-50 is a 1550 nm single-mode OTDR with an integrated optical power meter (OPM), 1550...
OFL250-50
Noyes Handheld OTDR
|
Model Number
|
Description
|
|
OFL250-50U-ENG
|
1550 nm, single-mode OTDR
|
***IN STOCK - DELIVERED TO YOUR SITE WITHIN 72 HOURS ****
OFL250-50 Handheld, Fault-Locating OTDR The Noyes OFL250-50 is a 1550 nm single-mode OTDR with an integrated optical power meter (OPM), 1550 nm laser source (OLS), and visual fault locator (VFL) in a handheld package weighing only 0.8 kg (1.7 lb). With short dead zone and mid-range dynamic range performance, the OFL250-50 is ideal for troubleshooting dark single-mode fibers in local area, metro area, and FTTx networks.
The OFL250-50 provides automatic and manual setup, precision event analysis, 12-hour battery life, internal data storage, and USB connectivity. OTDR and OPM test ports are equipped with tool-free adapters, which can be changed in seconds.
OTDR test results are saved as industry standard .SOR files, which can be transferred to a PC for viewing, printing, and analyzing with the supplied Windows® compatible software.
|
Features:
|
•
|
Rugged, handheld and light weight
|
|
•
|
1.5 m event dead zone |
|
•
|
26 dB dynamic range |
|
•
|
Integrated OPM, OLS, VFL
|
|
•
|
Tool-free, switchable adapters for OTDR and OPM ports |
|
•
|
Internal storage (>1000 OTDR traces in standard .SOR format) |
|
•
|
High-contrast display is clear and bright in any lighting condition, including direct sunlight |
|
•
|
Transfer test results to a PC via USB |
|
•
|
Rechargeable 12-hour Li-Ion battery or AC power |
|
•
|
Windows® compatible software to view, print, and archive test records
|
Applications:
|
•
|
Locate cable cuts, open or high-loss splices, fiber bends, and high-loss/high-reflectance connections
|
|
•
|
Measure optical power (OPM port) |
|
•
|
Short-range fault-location (VFL port) |
|
•
|
Trace fibers and measure end-to-end loss at 1550 nm (working with a Noyes optical power meter or light source)
|
|
•
|
Identify fibers (working with a Noyes optical fiber identifier) |
Specifications
|
OTDR
|
|
Emitter Type
|
Laser
|
|
Safety Class
|
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
|
|
Fiber Type
|
Single-mode
|
|
Center Wavelength
|
1550 nm
|
|
Wavelength Tolerance
|
± 20 nm
|
|
Dynamic Range (SNR=1)
|
26 dB
|
|
Event Dead Zone 1
|
1.5 m
|
|
Attenuation Dead Zone 2
|
7 m
|
|
Pulse Widths
|
5, 10, 30, 100, 300 ns, 1, 3, 10 μs
|
|
Range Settings
|
250 m to 256 km
|
|
Data Points
|
Up to 16,000
|
|
Data Point Spacing
|
12.5 cm (range < 4 km),Range/16,000 (range > 4 km)
|
|
Group Index of Refraction (GIR)
|
1.4000 to 1.6000
|
|
Distance Uncertainty (m)
|
± (1 + 0.005% x distance + data point spacing)
|
|
Trace File Format
|
Bellcore GR-196 V.1.1
|
|
Trace File Storage Medium
|
Internal memory (>1000 traces)
|
|
Data Transfer to PC
|
USB cable
|
|
OTDR Modes
|
Full Auto, End Locate, Expert, Live
|
|
Optical Power Meter
|
|
Calibrated Wavelengths
|
1310, 1490, 1550, 1625 nm
|
|
Detector Type
|
Filtered InGaAs
|
|
Measurement Range
|
+23 to - 45 dBm
|
|
Tone Detect Range
|
+3 to -35 dBm
|
|
Wavelength ID range
|
+3 to -35 dBm
|
|
Accuracy
|
± 0.25 dB
|
|
Resolution
|
0.01 dB
|
|
Measurement Units
|
dB, dBm, mW, nW
|
|
Optical Light Source
|
|
Emitter Type
|
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
|
|
Fiber Type
|
Single-mode
|
|
Center Wavelength
|
1550 nm
|
|
Wavelength Tolerance
|
± 20 nm
|
|
Spectral Width (FWHM)
|
5 nm (max)
|
|
Internal Modulation
|
1 kHz, 2 kHz
|
|
Output Power Stability
|
< ± 0.25 dB after 15 min
|
|
Output Power (nominal)
|
– 3 dBm
|
|
Visual Fault Locator
|
|
Emitter Type
|
Laser
|
|
Safety Class
|
Class II FDA 21 CFR 1040.10 and 1040.11,IEC 60825-1: 2007-03
|
|
Wavelength
|
650 nm
|
|
Output Power (nominal)
|
0.8 mW into single-mode fiber
|
|
General
|
|
Size (in boot)
|
19 x 11.2 x 4.7 cm (7.5 x 4.4 x 1.9 in)
|
|
Weight
|
0.8 kg (1.7 lb)
|
|
Operational Temperature
|
-10 to +50°C, 0 to 95% RH (non-condensing)
|
|
Storage Temperature
|
-20 to +60°C, 0 to 95% RH (non-condensing)
|
|
Power
|
Rechargeable Li-Ion or AC adapter
|
|
Battery Life
|
12 hours, backlight ON, continuous operation
|
|
Display
|
LCD, 320 x 240, 3.5 inch (89 mm), color, high-performance transflective with backlight and AR coating
|
|
|
Note: The OFL250-50 OTDR comes with a carry case, (1) SC and (1) FC adapter for the OTDR/OLS port, 2.5 mm adapter for the OPM and VFL ports, One-Click Cleaner SC/FC/ST (2.5 mm), USB cable (connects with Type A USB port on your PC), and AC power adapter with country-specific power cord.
|
Contact: Shel at 207-221-3154 website: TamgeStore.com - Tamge.com